5.1 WHAT IS OXYGEN PLANT
VepMed Blog
by admin
1y ago
Oxygen plant installation the high pressure coming from the cylinders to the hospital system plumbing and the Hospital Oxygen line to the desired pressure. It should consist of units that will send by lowering. Minimum 2 years of maintenance for the system, 10 years of parts for a fee. Availability guarantee should be given and this guarantee should be given by the company with an official document or letter to the hospital should be submitted to management. WHAT SHOULD BE CONSIDERED DURING OXYGEN PLANT INSTALLATION  There should be an automatic control panel in the oxygen plant. There s ..read more
Visit website
6.1 HOW TO MAKE MEDICAL GAS SYSTEM PIPING
VepMed Blog
by admin
1y ago
MEDICAL GAS SYSTEM PIPING PROCESS By preparing the medical copper pipe suspension elements, a suitable route is determined for the medical gas piping project. Medical copper pipe suspension elements are mounted on the route determined in accordance with the project. Afterwards, medical copper pipes are hung with rubber clamps suitable for the medical copper pipe diameters specified in the medical gas installation project. By using fitting materials suitable for medical copper pipe diameters, medical copper pipes are made suitable for welding. While welding oxygen butane, an inert gas (n ..read more
Visit website
2 .1 MEDICAL GAS INSTALLATION
VepMed Blog
by admin
1y ago
MEDICAL AIR MEDICAL GAS INSTALLATION FOR MEDICAL AIR, THERE MUST BE MINIMUM THREE SEPARATE SUPPLY SYSTEMS WITH AT LEAST ONE SUPPLY UNIT WITH COMPRESSOR. EVEN IF ONE OF THESE IS DISABLED, A SINGLE SYSTEM SHOULD BE ABLE TO FEED THE HOSPITAL ALONE.      ( TSE ISO EN 7396-1 p 12/5.5.2.4) MEDICAL AIR BLOCK DIAGRAM L: COMPRESSOR                                                             K: COMPRESSED AIR TANK      ..read more
Visit website
3.1 WHAT IS MEDICAL ZONE SERVICE UNIT
VepMed Blog
by admin
1y ago
What is Medical Zone Service Unit Medical Zone Service Units must be manufactured in such a way as to separate the sections it controls from the central gas system in order to provide regional control in case of emergency. There should be a visual inspection window on the front cover to help monitor gas pressures. Medical Zone Service Unit, there should be a shut-off valve for each gas type and a digital manometer with LCD display and vacuum meters showing the pressure of the gas. Valves should have union connections to ensure easy intervention and they should be welded with copper pipes and ..read more
Visit website
4.1 WHAT IS OXYGEN THERAPY DEVICE
VepMed Blog
by admin
1y ago
  Oxygen therapy device is used to reduce the effect of a disease or to provide energy conversion, by reducing the oxygen gas pressure in the tubes containing high pressure oxygen gas to a constant and low pressure such as 4 bar and transferring oxygen gas to the patient at a flow rate of 0-15 lt/min.  How To Use Oxygen Therapy Device ? The oxygen therapy device has a G3/4” connection thread and is fixed to the oxygen cylinder valve with a key. After the oxygen therapy device is ready, it should be checked with soap bubbles whether there is gas leakage between the tube valve and t ..read more
Visit website
1.1 WHAT IS OXYGEN FLOWMETER
VepMed Blog
by admin
1y ago
Oxygen Flowmeter is used to control the flow rate of gases drawn from the central medical gas system or medical gas cylinders. Oxygen Flowmeter is often used in adult, pediatric and neonatal patients as well as in general services. It can also be evaluated in other areas, including anesthesia management and ambulances. As VEPMED Medikal, we offer you a comprehensive range of Oxygen Flowmeters to meet your ongoing clinical needs. VEPMED Oxygen Flowmeter (Debimeter) product family includes oxygen flowmeters with a flow rate of 6lt/min, 15lt/min and 30lt/min. We can define the design of our produ ..read more
Visit website

Follow VepMed Blog on FeedSpot

Continue with Google
Continue with Apple
OR